.png)





|
Product |
Seplife® LXMS 10QN |
|
Appearance |
White to light yellow spherical beads |
|
Type |
Strong anion exchange resin |
|
Matrix |
Polystyrene/divinylbenzene |
|
Ligand |
Quaternary Amine |
|
Ion exchange capacity (mmol/ml) |
0.17-0.23 |
|
Particle size range (μm) |
10±1 |
|
Typical pore size (Å) |
55±10 |
|
pH stability |
2-12 (operation), 1-14 (CIP) |
|
Chemical stability |
Stable in commonly used aqueous ion exchange buffers |
|
Flow rate* (cm/h) |
≥360 (2.0 Mpa) |
|
Dynamic binding capacity** (mg/ml) |
≥55 |
|
Maximum Pressure resistance |
5.0 MPa / 50 Bar |
|
Shipped as |
Slurry in 20% ethanol solution |
*Testing conditions: chromatography column 10mm×200mm; Column bed height 10cm;
** Testing conditions:Column: I.D. 10mm×100mm,Binding buffer: 20mM Tris-HCl, pH7.0,Elution buffer: 20mM Tris-HCl, 1M NaCl, pH7.0,
Sample: BSA 5mg/ml, Retention time 4min.
The Seplife® LXMS 10QN resin is supplied as a 50-60 % (v/v) slurry in 20% ethanol solution. The use of a high ion strength mobile phase for resin packing into the chromatographic column (including cleaning and disinfection) is preferred; it is recommended to use 0.4-0.5 M NaCl, 0-20% ethanol solution can also be suitable. The recommended slurry concentration for column packing is 50-60%.
· Gently mix the resins to form a homogeneous slurry and transfer the desired mass or volume to the buffer exchange vessel. A volume of resin of approx. 1.2 times more than the desired column packed volume should be used.
· Before packing the column, adjust the homogenate concentration to 50-60 % with 0.4-0.5 M NaCl or 0-20% ethanol solution; pour the entire homogenate volume into the chromatography column at one time.
· Load the distribution plate and adjust the height, then start the pump and stabilize the column bed with
1.5 to 2 times the working flow rate or gradually increase the flow rate to reach a final pressure of 20-35 bar.
· Mark the bed height after the column bed is stabilized and adjust the height so that the compression coefficient is 1.05-1.10.
· Efficiency and symmetry determinations are performed according to SOP and must meet predetermined criteria.
Equilibrate the chromatographic column with mobile phase of 0.4M NaCl solution at a flow rate of 60cm/h for 5-10CV. Test the column efficiency using a mobile phase of 0.4M NaCl solution and injecting 0.5-1% column volume of 0.8M NaCl solution at 60cm/h flow rate. Using the conductivity detector, record the chromatogram and calculate the peak asymmetry and the theoretical plate number. Typically, the number of plates ≥ 12000/m, and the asymmetry factor is 0.8-1.5.
The packed columns should be rinsed with a minimum 5 CV of buffer.
After packing the column, equilibrate with the mobile phase first, with 5-10 column volumes, and control the flow rate at 120-300cm/h until the conductivity and pH of the flow-through remain unchanged before feeding the sample.
The solid sample can be prepared by dissolving in the equilibrium solution; the low-concentration sample solutions should be concentrated in advance as much as possible; the high concentration sample solutions can be diluted by the equilibrium solution. To avoid clogging of the column, samples should be processed by centrifugation or membrane filtration. The feed amount is calculated according to the capacity of the resin and the content of the target molecule in the feed solution. Before loading, make sure that the sample buffer should be as consistent as possible with the equilibration solution.
After loading the sample, continue rinsing with equilibration buffer until the baseline is stable. According to the actual situation, elute the samples adsorbed on the resin sequentially by increasing the salt concentration or changing the pH of the mobile phase.
Regular Cleaning-In-Place (CIP) can prevent column fouling, and help to maintain the capacity and resolution of the chromatographic media. Specific CIP methods and the frequency of CIP need to be designed for each process according to the type of contamination. The recommended regeneration and CIP method is as follows: Rinse the column up-flow with 5 CV of 1-2 M NaCl followed by 5 CV of 0.5-1 M NaOH.
Chromatography resins in bulk that are not for immediate use should be stored in 20% ethanol at 4-30 °C. The column packed with Seplife® LXMS 10QN , after regeneration, CIP and sanitization should be stored in a buffer solution containing 20% ethanol preferable at neutral pH.
|
Product Name |
References |
Pack Size |
|
Seplife® LXMS 10QN |
PS40323X(10)1-1 |
25ml |
|
PS40323X(10)1-2 |
100ml |
|
|
PS40323X(10)1-3 |
500ml |
|
|
PS40323X(10)1-4 |
1L |
|
|
PS40323X(10)1-5 |
5L |
|
|
PS40323X(10)1-6 |
10L |
Production date: See label
Expiry date: 5 years from manufacture, under proper storage conditions